NETSNMPD

Screenshot of the modules main screenThis module enables the SNMP agent on the NAS and allows to configure the agent. MIBs are installed with the module into the modules system/share/snmp/mibs directory.

Beside standard MIB support some monitoring and notification options can be configured through the WebUI directly. These are:

  • link up/down
  • swap space low
  • high system load

Further, a private MIB tree has been added to allow device specific events to be monitored. The MIB tree used is .1.3.6.1.4.1.14822.101.21 (or enterprises.fajo.vendor.thecus).

These additional MIBs are:

  • FAJO-SNMP-MIB
  • FAJO-VENDOR-THECUS-MIB

Currently the following additional objects are made available:

  • thecusIO.fan1rpm (thecusIO.1) - integer
  • thecusIO.fan2rpm (thecusIO.2) - integer
  • thecusIO.sysbpTemp (thecusIO.3) - integer (since 2.00.00)
  • thecusIO.cpuTemp (thecusIO.4) - integer (since 2.00.00)

Supported Models

This module should work for the following models:

1U4200XXX, N2310, N2800, 1U4500, N4310, N4510U, 1U4600, N4510UPRO, M3800, N4800, N0503, N4800Eco, N2200XXX, N5550, N2520, N2560, N3200PRO, N6850, N3200XXX, N7510, N4100PRO, N7700PROv2, N4200, N8800PROv2, N4200Eco, N8900, N4200PRO, N8850, N4520, N8900V, N10850, N4560, N12000, N5200, N12000PRO, N5200PRO, N12000V, N5200XXX, N16000, N5500, N16000PRO, N7700, N16000V, N7700+, N7700PRO, N7700SAS, N8200XXX, N8800, N8800+, N8800PRO, N8800SAS

Note: thecusIO may not provide valid data on all models.

Installation

Extract the module binary package (.mod or .app) from the archive and install it.

Configuration

Note: For this module to work, the integrated SNMP service has to be disabled if the SNMPD standard port is to be used.

After enabling the module the module configuration page can be accessed. Configuration parameters are explained at the bottom of the configuration page.

Starting with 1.01.00 it is possible to completely customize the configuration using the advanced configuration textbox on the configuration screen. This will allow one to add monitors or configure SNMPv3 access controls.

Feature Requests

Further Reading

Attachments

AttachmentSize
[file] NETSNMPD 2.00.00
MD5: 982a14a7b11a32f44cfea175e733c696
2.58 MB
[file] FAJO-SNMP-MIB590 bytes
[file] FAJO-VENDOR-THECUS-MIB1.25 KB